Wednesday, October 5, 2016

server HP ML350 G5 tidak bisa booting [red internal System health LED]

Bismillah...
kemarin salah satu server kami (server HP Ml350 G5) tidak bisa booting setelah lama tidak di hidupkan , salah satu indikator led menyala dengan warna mearah berkedip (flashing) ,

photo_2016-10-05_10-00-23

berikut informasi  HP ProLiant ML370 G5 Server - LEDs and Buttons


Systems Insight Display LEDs


To view a quick reference for component identification and status, access the Systems Insight Display.

























































































Item

Description

Status

1

Primary power supply LED

Amber = Failure

Off = Normal

2

Redundant power supply LED

Amber = Failure

Off = Normal

3

Online spare memory LED

Green = Protection enabled

Amber = Memory failure occurred

Flashing amber = Memory configuration error

Off = No protection

4

Mirrored memory LED

Green = Protection enabled

Amber = Memory failure occurred

Flashing amber = Memory configuration error

Off = No protection

5

FBDIMM LEDs* (memory board 1)

Amber = Failure

Off = Normal

6

FBDIMM LEDs* (memory board 2)

Amber = Failure

Off = Normal

7

Processor 1 LED

Amber = Failure

Off = Normal

8

PPM 1 LED

Amber = Failure

Off = Normal

9

Processor 2 LED

Amber = Failure

Off = Normal

10

PPM 2 LED

Amber = Failure

Off = Normal

11

Hot-plug fan LEDs

Amber = Failure or fan is not installed

Off = Normal

12

Internal system health LED

Green = Normal (system on)

Amber = System health is degraded

Red = System health is critical

Off = Normal (system off)

13

External system health LED (power supply)

Green = Normal (system on)

Amber = Redundant power supply failure

Red = Power supply failure. No operational power supplies.

Off = Normal (system off)

14

Overtemperature LED

Red = Overheating, critical

Off = Normal

15

System power LED

Green = System has AC power and is powered on

Amber = System has AC power and is in standby mode

Off = System has no AC power


* If all FBDIMM LEDs for a memory board are flashing, the memory board is unseated.


 

nah untuk menangani nya , dari beberapa saran di forum HP ,

langkah pertama cabut  baterai dari system board , langkah ke dua cabut memori board kemudian masukan lagi, langkah ke tiga masukan lagi baterai ke system board(mother board)  terakhir  coba boot lagi ,

dari saran di atas jika masih belum bisa boot dan led Internal system health masi menyala merah , di langkah ke dua setelah cabut memori board , cabut juga satu persatu memori nya kemudian pasang lagi dan coba boot ulang.

semoga bermanfaat  :)

referensi:

https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/ML350-G5-won-t-boot-red-internal-health-LED-undocumented-system/td-p/4831011

http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c00745284

 

No comments: