kemarin salah satu server kami (server HP Ml350 G5) tidak bisa booting setelah lama tidak di hidupkan , salah satu indikator led menyala dengan warna mearah berkedip (flashing) ,
berikut informasi HP ProLiant ML370 G5 Server - LEDs and Buttons
Systems Insight Display LEDs
To view a quick reference for component identification and status, access the Systems Insight Display.
Item | Description | Status |
1 | Primary power supply LED | Amber = Failure Off = Normal |
2 | Redundant power supply LED | Amber = Failure Off = Normal |
3 | Online spare memory LED | Green = Protection enabled Amber = Memory failure occurred Flashing amber = Memory configuration error Off = No protection |
4 | Mirrored memory LED | Green = Protection enabled Amber = Memory failure occurred Flashing amber = Memory configuration error Off = No protection |
5 | FBDIMM LEDs* (memory board 1) | Amber = Failure Off = Normal |
6 | FBDIMM LEDs* (memory board 2) | Amber = Failure Off = Normal |
7 | Processor 1 LED | Amber = Failure Off = Normal |
8 | PPM 1 LED | Amber = Failure Off = Normal |
9 | Processor 2 LED | Amber = Failure Off = Normal |
10 | PPM 2 LED | Amber = Failure Off = Normal |
11 | Hot-plug fan LEDs | Amber = Failure or fan is not installed Off = Normal |
12 | Internal system health LED | Green = Normal (system on) Amber = System health is degraded Red = System health is critical Off = Normal (system off) |
13 | External system health LED (power supply) | Green = Normal (system on) Amber = Redundant power supply failure Red = Power supply failure. No operational power supplies. Off = Normal (system off) |
14 | Overtemperature LED | Red = Overheating, critical Off = Normal |
15 | System power LED | Green = System has AC power and is powered on Amber = System has AC power and is in standby mode Off = System has no AC power |
* If all FBDIMM LEDs for a memory board are flashing, the memory board is unseated.
nah untuk menangani nya , dari beberapa saran di forum HP ,
langkah pertama cabut baterai dari system board , langkah ke dua cabut memori board kemudian masukan lagi, langkah ke tiga masukan lagi baterai ke system board(mother board) terakhir coba boot lagi ,
dari saran di atas jika masih belum bisa boot dan led Internal system health masi menyala merah , di langkah ke dua setelah cabut memori board , cabut juga satu persatu memori nya kemudian pasang lagi dan coba boot ulang.
semoga bermanfaat :)
referensi:
https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/ML350-G5-won-t-boot-red-internal-health-LED-undocumented-system/td-p/4831011
http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c00745284
No comments: